d62675001045c57fb89f5180f1c45d07fe8227ba
3 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
4efd70c987 |
vyos: move PPPoE off the config plane onto a gated systemd unit
Some checks failed
PPPoE HA could not work as written, and the reason is structural rather than a
bug: `set interfaces pppoe pppoe0 disable` and `delete` are handled identically
by interfaces_pppoe.py -- both UNLINK /etc/ppp/peers/pppoe0. That path is pppd's
own options file, so the resting state destroyed exactly what the promotion path
needed, and `ppp@pppoe0` restart-looped against it (observed: 47 restarts, zero
sessions at the access concentrator). It also made op-mode `connect interface
pppoe0` unusable, and put every failover behind a priority-322 commit where one
unrelated invalid node fails the whole thing -- which has already taken the
10 gig down once.
pppoe0 is now configured identically and ENABLED on both routers, so the peers
file always exists, and dialling is gated by a drop-in on the unit:
ConditionPathExists=/run/vrrp-wan/may-dial
ConditionPathExists=/etc/ppp/peers/pppoe0
/run is tmpfs, so the gate is shut at boot and neither box can dial before VRRP
has decided. That matters more than it first appears: with the node enabled,
interfaces_pppoe.py restarts ppp on EVERY commit touching the pppoe subtree when
the daemon is not running -- so the backup actively tries to dial whenever
anything commits. The gate is the only thing making that a no-op, which is why
vrrp-wan-reconcile now refuses to bless a box whose drop-in is missing: /etc is
per-image, and a VyOS upgrade would otherwise silently remove the protection.
may-dial is a LEASE, not a flag. ConditionPathExists is evaluated at start only
-- it can prevent a dial, never revoke one -- so a reconciler that stops running
while its box is demoted would keep the one ISP session for ever. The reconciler
renews the lease; a new 5s vrrp-wan-guard revokes it, and only ever revokes. It
fired correctly first time: "GUARD: lease stale (81s > 75s)".
Also: remove-then-stop on release (the file's absence blocks a NEW start that a
concurrent commit would trigger); a flap damper, because two routers that both
believe they hold the VIP will both dial and each dial kills the other's session
-- against a real ISP that is how an account gets rate-limited; and a guard on
`cfg` returning empty under commit-lock contention, which had already produced
one spurious "releasing" on a box that needed nothing.
GRACE 90 -> 180. accel-ppp's dead-peer budget is lcp-echo-interval(30) x
failure(3) = 90s, so the old value sat exactly on the boundary: a hard failover
into an AC that does not replace the stale session would fail its own check,
shed the VIPs, and leave both routers in FAULT.
The sim could not have tested any of this. Both routers now get the identical
WAN -- the secondary had none "because two PPPoE clients sharing one credential
is a different failure mode than anything production has", which is backwards:
that IS production. It also left the pair incomparable, ten NAT rules against
none. Safety now comes from resting state, not asymmetry.
Three more things the sim was hiding:
- the drift check's secondary regex omitted interfaces pppoe/bonding, nat
source and protocols failover, so it reported "in sync" for a box with no
WAN at all;
- the VRRP health-check and transition-script hooks existed on both live VMs
and in NEITHER generator -- the mechanism under test was pure undetected
drift;
- labsim-vyos's only default route was the libvirt-NAT scaffold, so every
"the LAN still has internet" verdict on it was answered by eth2 rather than
the WAN. --drop-scaffold applied; the earlier DHCP-failover proof is being
re-run because of it.
vrrp-wan-install ends the other half of that: the sim's previous proof came from
scripts hand-`sed`-ed in place, so the tested behaviour was not the committed
behaviour. `--check` now makes that a hard failure.
First green run: master holds both WANs, backup released, and the AC reports
exactly ONE session. sim-net-apply.sh check: all four in sync.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DMVzWZgiKW2wquf5z8S1yH
|
||
|
|
0481c38e09 |
labsim: prove the tagged-Management fix for kea's wrong-pool offers
Kea #1117: with dhcp-socket-type raw, a frame tagged for a sub-interface is also delivered to the parent's AF_PACKET socket, and if the parent serves a subnet kea answers from it too. Management being the native VLAN on bond0 is what gives the parent that subnet. One DISCOVER on VLAN 3 produced two OFFERs, and in the captures here the WRONG one arrives first as often as not -- which is why this looked device-dependent rather than like a server bug. labsim-vlan-leak-test.sh reproduces it and scores the SERVER's offers, not the client's choice; a client picking correctly is how this hid. Fails on the old shape, passes on the new one across all six LAN VLANs. Three things the rehearsal caught that reasoning had not: - kea keeps its old raw socket. VyOS does not restart it for an interface address change, so the first post-fix test failed and looked exactly like the fix not working. - interface-group LAN names the bare bond0. Moving the address without moving the group drops every management session under default-deny. - there is no make-before-break. A port always egresses its native VLAN untagged, so while VLAN 1 is native the router can send tagged VLAN 1 but never receive it -- verified, the ARP landed on bond0 untagged. What makes the cutover safe anyway is that tagged and untagged Management coexist, so the firewalls convert one at a time: 0s of VIP downtime, versus 5m30s if both routers go before the switch does. In that state the healthy BACKUP does NOT take over -- the sync group holds native BACKUP because the other VLANs still hear the master. Also fixes two ways the sim was lying. ovs_bond_router compared only the trunk VLAN list on re-runs, so a VM restart left the bond holding taps that no longer existed while the real ones sat in the bridge unbonded -- labsim-vyos2 had no LACP at all. And the tap count included the primary's libvirt-NAT scaffold NIC, so the primary's bond was skipped outright. Runbook: migration/MANAGEMENT-VLAN-TAGGED.md Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DMVzWZgiKW2wquf5z8S1yH |
||
|
|
bb654d83f8 |
test(labsim): second VyOS router proves DHCP active-passive HA
Answers the question a single router could not, and that would otherwise only
have been discovered at cutover: with kea high-availability active-passive, does
exactly ONE box answer a DHCP request?
Yes. Probing sim VLAN 10 with broadcast-dhcp-discover returns offers from a
single distinct Server Identifier -- 172.31.10.252, the primary. The secondary
runs kea but stays silent. Without this the delta would have put 6 subnets and
84 static-mappings on both boxes with nothing to arbitrate them, and two kea
instances would have raced on every broadcast domain.
Worth noting the raw response count is misleading: nmap reports "Response 1 of
2" because it sends several discovers, and both replies carry the same server
identifier. Counting responses says "2 servers"; counting distinct server
identifiers says "1". The second number is the true one.
labsim now runs a real pair, mirroring production:
router1 172.31.<v>.252 priority 200 DHCP HA primary
router2 172.31.<v>.253 priority 100 DHCP HA secondary
VIP 172.31.<v>.1 floating, held by the master
That required converting router1, which held .1 directly, to .252 plus a
floating VIP -- otherwise it is two routers, not a pair. All six VRRP groups
show MASTER on router1 and BACKUP on router2.
New tooling:
- sim-ha-config.py generates each role's config, reusing unifi-to-vyos.py
--mode sim for the DHCP half so what is proven here and what production
gets share a code path. VLAN 10 correctly carries /23.
- console-apply.py applies config over the serial console, which is necessary
because a freshly installed VyOS holds the same addresses as its peer and
cannot safely be reached over the network at all until reconfigured.
Known sim-only quirk, deliberately not chased: router1 cannot ARP router2 on
the untagged VLAN 1 while every tagged VLAN works, and VRRP forms correctly on
all six groups regardless. Both OVS bonds carry identical vlan_mode/tag/trunks
and the bond MACs differ, so this is OVS bond behaviour on the native VLAN with
two bonds on one bridge -- not a VyOS config problem, and not present in
production, which uses a real switch.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DMVzWZgiKW2wquf5z8S1yH
|