A VM that installs fine but never reaches SSH was destroyed by afterAll
with the only evidence -- its console -- inside it. Now the failure
carries the last serial lines and domstate, and KEEP_VMS=1 preserves
the machine for inspection.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V6HNx6cyr4J4CiMGCy1wkF
One real-VM test mirroring thebeast's topology: OS disk + two data disks
addressed by /dev/disk/by-id/ (virtio serials standing in for NVMe
serials). Fresh k8s-worker v2 install must put labelled whole-disk xfs
on each data disk and drop the matching LVs; a flagless reprovision must
rediscover both by label and remount them unformatted -- proven by
marker files AND unchanged filesystem UUIDs.
Harness: createPxeVm grows dataDisks (extra virtio disks with fixed
serials, <=20 chars or the guest by-id link truncates), provisionVm
passes the by-id paths to /api/install, virtioById exported.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V6HNx6cyr4J4CiMGCy1wkF
The fleet's disk layout was decided by literal role-name comparisons at 17
sites across 8 files. That is why `labcontroller` got no rancher LV (it
matched neither "infra" nor "worker"), why labmaster carried an empty 728 GiB
Longhorn LV, and why a 62 GiB container image tipped that node into
DiskPressure and evicted bastion, labd, cockroach and openbao.
Three generators each hardcoded their own sizes and disagreed: the kickstart
said rancher=120G, ubuntu-autoinstall said 20G, asahi-firstboot said 20G under
a comment asserting the sizes matched install.ks.ts. They did not.
ROLE_REGISTRY already carried `k3s` and `parent` and nothing read them. This
makes capabilities authoritative, moves every size into one shared module, and
adds schema v2 (fixed 250G rancher / 300G longhorn, never --grow). Existing
machines stay v1 forever: schema is detected from the on-disk VG tag, so a v1
box stays v1 even when v2 is requested.
Proven on real VMs, not just unit tests: all four topologies installed and had
their layouts read back off the machines; markers in /home, /srv,
/var/lib/longhorn and /var/lib/rancher survived reinstall; and a 4-node cluster
formed, took real data, and had all three servers rolled one at a time through
evacuate / wipe / reinstall / rejoin with checksums verified before and after
each roll. Drill: 10/10, evidence in migration/drill-evidence/.
Production defects the drill found, none of which a unit test could reach:
- sshOpts() capped every operation at 30s while drainNode asked kubectl for
--timeout=15m, so the transport killed the drain after evicting most pods and
returned a transcript that read like success. `labctl app k3s evacuate` could
never have drained a real node.
- generateAgentConfig put node-role.kubernetes.io/worker in the kubelet's
node-label list, which NodeRestriction rejects, so no agent installed through
K3sModule could start. systemd reported only "did not take the steps required
by its unit configuration".
- toOpContext built K3sConfig by enumerating three keys and silently dropped
the rest, so the k3s version pin did nothing and --allow-single-replica was a
no-op that claimed to override a data-loss guard.
- The Longhorn disk annotation was mangled by shell quoting; with
createDefaultDiskLabeledNodes the node then gets no disk at all, joins, goes
Ready, and silently hosts no replica.
- evacuate drained before evicting, which blocks on Longhorn's PDBs and would
destroy a single-replica volume's only source.
- etcd member ids were parsed from JSON, losing uint64 precision and emitting
decimal where `member remove` needs hex -- at the moment a node is stopped
and about to be wiped.
- get.k3s.io installs latest, two minor versions ahead of the fleet, so a
reinstalled node would rejoin on a newer k3s than its peers and roll an
unplanned two-version control-plane upgrade. K3sConfig.k3sVersion now pins it.
- `labctl app k3s install --role x` mapped anything that was not "worker" to
"infra", so the runbook's own `--role k8s-combo` would have installed a
different role with different disk expectations and no warning.
Also: /var/lib/longhorn/replicas must never be deleted, only its contents, or
every replica placed on the node dies on a non-recursive mkdir -- for ever,
while the node reports Ready, Schedulable and healthy.
etcd is now in the kickstart's package set for k3s server roles, because
`k3s etcdctl` is not a command and a member that needs to recover its own
membership has no internet.
542 unit tests / 39 files.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Both Protectli VP2440s failed to install on real hardware: they fetched
kernel+initrd and then went silent. The console showed why —
Looking for a connected Ethernet interface ... e2 ? e3 ? e4 ? e5 ?
Connected e4 found
Connected e5 found
[4.595647] igc 0000:02:00.0 e2: NIC Link is Up
IP-Config: e4 ... no response after 15 secs - giving up
Unable to find a live file system on the network
live-boot picks the first *connected* interface. The i40e SFP+ pair links
before the igc copper port (up at 4.6s), so it chose the fiber ports, which
have no DHCP, and never tried the NIC that actually PXE booted.
Fix: pass BOOTIF=01-<mac> on the kernel cmdline. live-boot's
Device_from_bootif() (verified present in this image) matches it against
/sys/class/net and sets DEVICE directly. The MAC comes from the dispatch
key — i.e. exactly the NIC that PXE booted — which is more reliable than
iPXE's ${net0} on a box where the booting NIC may not be net0.
Why the integration test missed it: the VM had ONE NIC, so "first connected
interface" was trivially correct, and virtio links instantly so there was no
negotiation race. createPxeVm now takes decoyNics, attaching extra NICs
ahead of the PXE NIC on a network with no route to the bastion; the VyOS
test uses 2. Without BOOTIF that reproduces the hardware failure. getVmMac
is network-aware so it still returns the booting NIC.
Also: the bastion had every clue and said nothing — it logged INSTALL
STARTED, served kernel+initrd, then nothing for 7 minutes. dispatch now
stamps dispatched_at, and /api/logs/:mac returns stalled_for_s / stalled
(8 min threshold, sized for the ~600MB squashfs fetch), so a machine wedged
before the installer environment comes up is diagnosable without a console.
Verified on hardware: both firewalls installed, bond0 802.3ad + VLANs
2/3/9/10/200 + VRRP (priority 200/100, VIP .254 per VLAN) applied, and
/config/lab-provisioned written.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DMVzWZgiKW2wquf5z8S1yH
- logging --host blocks Anaconda when syslog UDP port not reachable
- nomodeset prevents amdgpu hang on SER9MAX (Radeon 780M)
- JetKVM helper script for device control (status, reboot, power)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
All accumulated changes to kickstart template, test infrastructure,
and dnsmasq config. None of these produce a clean boot yet — saving
state before reverting to baseline for bisection.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- VMs get serial console on TCP (PXE: port 4555, ISO: port 4556)
- serialExec() helper: runs commands via telnet when SSH/network is down
- PXE test: on SSH failure, dumps hostname, IP, NetworkManager, sshd,
failed units, and fstab via serial console before failing
- Kickstart enables serial-getty@ttyS0 for auto-login on serial
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
ARM integration test:
- arm-iso-provision.test.ts: aarch64 VM boots from bastion-generated ISO
- Uses QEMU aarch64 emulation (slow but validates the R1 scenario)
- Generous timeouts for emulated boot (15min discovery, 60min install)
- test-provision.sh updated: `sudo ./scripts/test-provision.sh arm`
VM boot fixes:
- setBootDisk() preserves UEFI loader/nvram when switching to disk boot
- /boot/efi mount gets nofail in fstab (prevents emergency mode in VMs)
- chronyd enable uses || true (fails in kickstart chroot)
- createIsoVm supports arch parameter for ARM VMs
Note: SSH-after-reboot in OVMF VMs still fails — OVMF doesn't respect
efibootmgr changes and loops PXE/HTTP Boot. Real hardware works fine.
The install flow itself (discovery → kickstart → complete) is validated.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Kickstart installs on real hardware failed silently — no error reporting,
only 3 progress callbacks, zero log streaming. This overhaul makes every
install fully observable.
Kickstart improvements:
- Error trapping in %pre and %post (trap ERR sends failure details to bastion)
- 12+ granular progress stages (was 3): SSH, hostname, k3s prep, EFI boot, metadata
- Background log streamer: tails %post output and batch-sends to /api/log
- bastion_log() function for explicit log lines from kickstart scripts
Bastion API:
- POST /api/log — receives raw log lines from kickstart (single or batch)
- InstallLogBuffer — per-MAC ring buffer (2000 lines) + file persistence
- GET /api/logs/:mac — now returns log_lines + log_total alongside stages
- SSE /api/logs/:mac/follow — uses named events (event: stage vs event: log)
- Progress events forwarded to labd via bastion-progress WebSocket message
- Post-provision k3s logs routed through progressBus (was console-only)
dnsmasq fixes found during VM testing:
- HTTP Boot filename: ipxe-real.efi → ipxe.efi (leftover from old 2-stage approach)
- pxe-service directives: only in proxy mode (breaks OVMF PXE in full mode)
- PXEClient vendor class echo for UEFI firmware compatibility
Integration tests:
- PXE boot test: blank UEFI VM → dnsmasq → HTTP Boot → iPXE → bastion → install
- ISO boot test: blank VM boots from bastion-generated ISO → same flow
- Shared helpers: pxe-network (no DHCP, nftables fix), pxe-vm (UEFI + ISO boot)
- test-provision.sh: runs both PXE + ISO tests with prerequisite checks
- 250GB sparse QCOW2 disk (LVM layout needs ~204GB)
201 unit tests passing (11 new).
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>